Class III Biosafety Cabinet

Maximum containment through a fully enclosed, gas-tight working chamber
GETRUS Class III Biosafety Cabinets are fully enclosed, ventilated cabinets of gas-tight construction. Operations are conducted through attached rubber gloves while the cabinet is maintained under negative pressure at least 0.5 inches water gauge. Supply air enters through HEPA
filtration, and exhaust air passes through two HEPA filters installed in series before discharge outside the facility.
Airflow & Lighting
Interlock
Motorized
Front Window
Dual HEPA
Filtration
ECM Motor

Key Advantages

â™™
Gas-Tight Construction
Maximum containment through a fully enclosed, gas-tight working chamber.

♜
Enclosed Port-Operation
Operations are conducted through attached rubber gloves.

â—·
Negative-Pressure Chamber
The cabinet is maintained under negative pressure of at least 0.5 inches water gauge.

â–¥
Double HEPA Exhaust
Exhaust air passes through two HEPA filters installed in series before discharge outside the facility.

â–¡
Side Transfer Chamber
Enables the transfer of materials without compromising containment.

â–£
Remote-Control Operation
Microprocessor-based control with optional HMI + PLC.

Technical Specifications
Front Window 5 mm transparent glass
Main Body Powder-coated electro-galvanized steel
Pressure Control Negative pressure of at least 0.5 inches water gauge
Supply Air HEPA-filtered
Exhaust Filtration Two HEPA filters installed in series
Exhaust System Separate external exhaust fan
Plenums Double-wall plenums
Mobility Floor-standing, portable and mobile configuration
Controls Microprocessor-based control; optional HMI + PLC
Lighting Concealed fluorescent light panel and germicidal UV lamp

Containment Applications

â™™
Maximum-Containment
Work

♜
Enclosed Glove-Port
Operations

â—·
Negative-Pressure
Processing

â–¥
Double HEPA Exhaust
Filtration

â–¡
Controlled Side
Transfer

Built for Maximum Containment

â™™
Gas-Tight Chamber
Fully enclosed and constructed for maximum containment.

â—·
Controlled Negative Pressure
Maintained under negative pressure of at least 0.5 inches water gauge.

â–¥
Double HEPA Exhaust
Highest air passage through two HEPA filters in series before discharge outside the facility.

â™§
Need Help Choosing the Right Equipment?
Tell us about your application and laboratory requirements. Our team will help you compare suitable options and select the equipment that best fits your needs.